installedgenerator

How we price

How installedgenerator.com compiles installed-cost figures from published cost guides and price lists, and how the sizing helper turns appliances into a generator size.

Sizing data checked November 18, 2026

Where the cost figures come from

Nobody publishes one true price for an installed generator: a quote depends on the unit, the distance to the gas meter and the electrical panel, the transfer switch, the permit and the installer's labor rate. The pages here report what the publishers that track these jobs say, each by name, with the date the page was read. Where two or more independent publishers agree on a range, a page may call it typical; a figure only one publisher gives is stated as that publisher's figure.

Unit prices come from a named seller's listing on a named date, so that several brands are compared on one footing; where a maker lists its own starting MSRP, as Generac does on its product pages, the page says so. Ratings, fuel use and maintenance intervals come from the makers' spec sheets and manuals.

What the desk does not do

The desk does not install generators, has not collected quotes of its own and does not survey installers. When a page says what an installation includes or how long it takes, it reports what makers and cost publishers state. Your installer's quote, made after a visit to your house, is the number that counts.

How the sizing helper works

The helper adds the running watts of everything ticked, adds the largest single motor's extra starting watts on top (motors start one at a time), and names the smallest standard air-cooled size whose rating on your fuel covers that peak. The method follows the wattage charts published by Champion Power Equipment and Briggs & Stratton.

The sizes are Generac's current air-cooled models, the most common residential line. A generator is usually rated the same or higher on propane than on natural gas, so the helper checks the rating for the fuel you choose. Generac's current air-cooled line (the Next Gen models), ratings from its spec sheets Rev. D 08/13/2026. The 10 kW is rated 9 kW on natural gas on the sheet and 10 kW on Generac's product page; the helper uses the lower figure. Older Guardian-series sheets, still printed by some sellers, rate the 22, 24 and 26 kW lower on natural gas (19.5, 21 and 22.5 kW).

SizeRating on propaneRating on natural gas
10 kW10,000 W9,000 W
14 kW14,000 W14,000 W
18 kW18,000 W17,000 W
22 kW22,000 W21,000 W
24 kW24,000 W22,500 W
26 kW26,000 W24,000 W
28 kW28,000 W25,000 W

Wattage charts from different makers disagree, sometimes by a factor of three for the same appliance. The helper uses one figure per load and says where it comes from. The nameplate on your own appliance, or a load calculation by an electrician, beats any chart.

Keep the house safe

LoadRunning wattsStarting wattsWhere the figure comes from
Refrigerator7002,900Generac, Champion Power Equipment: running from Generac's wattage worksheet (charts range from 200 to 1,200 W running); starting = that running figure plus the 2,200 W extra starting watts on Champion's chart
Chest or upright freezer5001,000Briggs & Stratton, Portlandia Electric Supply: Briggs & Stratton's chart: 500 W running plus 500 W additional starting watts (a dealer chart, Portlandia Electric Supply, gives 1,000 W of additional starting watts)
Sump pump, 1/2 hp6001,500Kohler: Kohler's motor table for a 1/2 hp motor
Well pump, 1 hp1,1003,300Kohler: Kohler's motor table for a 1 hp motor
Furnace blower, 1/2 hp6001,500Kohler: Kohler's motor table for a 1/2 hp motor
Lights600600Generac: Generac's wattage worksheet; lights have no starting surge
Computer and router400400Generac: Generac's wattage worksheet (computer); no starting surge
Television300300Honda Power Equipment: Honda's example list; no starting surge
Garage door opener, 1/2 hp4801,000Briggs & Stratton: Briggs & Stratton's chart: 480 W running plus 520 W additional starting watts

Kitchen and laundry

LoadRunning wattsStarting wattsWhere the figure comes from
Microwave1,5001,500Honda Power Equipment, Generac: Honda's example list and Generac's worksheet (1,500 W); Champion lists 800 W
Electric range, one element at a time2,0002,000Champion Power Equipment, HomeGuide: Champion's chart (electric stove) and HomeGuide; a whole range with every element on draws more
Dishwasher1,2002,700Champion Power Equipment: Champion's chart lists the extra starting watts, so starting = running plus that extra (1,200 + 1,500)
Washing machine5001,700Champion Power Equipment: Champion's chart lists the extra starting watts, so starting = running plus that extra (500 + 1,200)

Large electric loads

LoadRunning wattsStarting wattsWhere the figure comes from
Electric clothes dryer5,5005,500Portlandia Electric Supply, HomeGuide: a dealer chart (Portlandia Electric Supply) for a 240-volt dryer; Champion's chart lists 1,000 W, HomeGuide 3,000 W
Electric water heater, 40 gallons4,0004,000Briggs & Stratton: Briggs & Stratton's chart; no starting surge
Window air conditioner, about 10,000 BTU1,2003,200Champion Power Equipment, Briggs & Stratton: Champion's chart lists the extra starting watts, so starting = running plus that extra (1,200 + 2,000); Briggs & Stratton lists 1,200 W running and 1,800 W additional
EV charger, Level 27,2007,200HomeGuide, Portlandia Electric Supply: HomeGuide and a dealer chart (no maker's chart lists it); Generac names EV chargers among the loads a load manager can switch off

Central air conditioning

SizeRunning wattsStarting watts
2 ton2,5007,000
3 ton3,6009,600
4 ton4,80012,300
5 ton6,00015,000

Central air figures come from one dealer chart, the only source found with watts for every size; its surge column is labelled "Motor-Start Surge (Additional)", so the helper adds it to the running watts (a 3-ton unit: 3,600 W running, 9,600 W while starting). The same chart's worked example uses a smaller surge, and Champion lists a 3-ton unit at 5,000 to 6,000 W of extra starting watts (a peak of 8,000 to 9,500 W), close to this reading, so the helper takes the larger, label-faithful reading. A compressor without a soft-start kit can draw far more while it starts: Generac puts a 3-ton unit at about 3,500 to 5,000 W running and up to 15,000 to 18,000 W starting, so the helper can name a size too small for a hard-starting compressor. Central air rows corrected November 17, 2026. Generac's sizing page explains the soft-start kits and load managers installers use to avoid that.

When the figures change

Each page shows the date its figures were checked. Cost pages are read again at least every 90 days, and a figure that has moved is changed together with that date.

Mistakes

If a figure looks wrong, write to the desk through the address on the About page with the page and the figure. A confirmed error is fixed and the page's checked date moves.